Product details
Spot an error? Let us know!
Headline
Use in hazardous areas
ifm electronic offers a multitude of inductive sensors for use in hazardous areas - from threaded and rectangular types to dual sensors for position feedback on quarter-turn actuators. Numerous international approvals allow the use of the sensors in dust or gas Ex areas.
Sensors of categories 3G/3D or 2D can be connected directly to the plant control. The housings and housing parts of these units and of the corresponding connectors of the EVCxxA series were tested with an impact energy of 4 joules.
Features & Benefits
- Cylindrical or rectangular types
- 3D/3G: Robust full metal and plastic housings with 4 joules shock test
- Sensors with NAMUR interface for connection to switching amplifiers
- Simple connection using connector or terminals
- High mechanical stability
Additional Notes
MPN | Sensing range | Operating distance | Output function | Output | Dimensions |
---|---|---|---|---|---|
ID002A | 60 mm | 0...48.6 mm | normally open / closed; (selectable) | AC/DC | 105 x 80 x 42 mm |
IF503A | 3 mm | 0...2.43 mm | normally open | DC PNP | M12 x 1 / L = 60 mm |
IF504A | 3 mm | 0...2.43 mm | normally closed | DC PNP | M12 x 1 / L = 60 mm |
IF505A | 6 mm | 0...4.9 mm | normally open | DC PNP | M12 x 1 / L = 70 mm |
IF508A | 4 mm | 0...3.24 mm | normally open | DC PNP | M12 x 1 / L = 45 mm |
IF509A | 4 mm | 0...3.24 mm | normally open | DC PNP | M12 x 1 / L = 45 mm |
IG001A | 8 mm | 0...6.48 mm | normally open | AC/DC | M18 x 1 / L = 80 mm |
IG510A | 5 mm | 0...4.05 mm | normally open | DC PNP | M18 x 1 / L = 70 mm |
IG511A | 12 mm | 0...9.72 mm | normally open | DC PNP | M18 x 1 / L = 70 mm |
IG512A | 5 mm | 0...4.05 mm | normally closed | DC PNP | M18 x 1 / L = 70 mm |
IG513A | 8 mm | 0...6.48 mm | normally open | DC PNP | M18 x 1 / L = 80 mm |
IG514A | 10 mm | 0...8.1 mm | complementary | DC PNP | M18 x 1 / L = 80 mm |
IG515A | 8 mm | 0...6.48 mm | normally open / closed; (selectable) | DC PNP/NPN | M18 x 1 / L = 80 mm |
IG519A | 8 mm | 0...6.48 mm | normally open | DC PNP | M18 x 1 / L = 45 mm |
IG520A | 8 mm | 0...6.48 mm | normally open | DC PNP | M18 x 1 / L = 45 mm |
II502A | 10 mm | 0...8.1 mm | normally open | DC PNP | M30 x 1.5 / L = 65 mm |
II503A | 25 mm | 0...20.3 mm | normally open | DC PNP | M30 x 1.5 / L = 65 mm |
II505A | 15 mm | 0...12.15 mm | normally open | DC PNP | M30 x 1.5 / L = 50 mm |
II506A | 15 mm | 0...12.15 mm | normally open | DC PNP | M30 x 1.5 / L = 50 mm |
IM001A | 20 mm | 0...16.2 mm | normally open / closed; (selectable) | AC/DC | 40 x 40 x 105 mm |
IM002A | 40 mm | 0...32.4 mm | normally open / closed; (selectable) | AC/DC | 40 x 40 x 105 mm |
IM506A | 20 mm | 0...16.2 mm | normally open / closed; (selectable) | DC | 40 x 40 x 105 mm |
IM510A | 20 mm | 0...16.2 mm | complementary | DC | 40 x 40 x 105 mm |
IM511A | 40 mm | 0...32.4 mm | complementary | DC PNP | 40 x 40 x 54 mm |
IM512A | 20 mm | 0...16.2 mm | complementary | DC PNP | 40 x 40 x 54 mm |
IM513A | 30 mm | 0...24.3 mm | complementary | DC PNP | 40 x 40 x 54 mm |
IN507A | 4 mm | 2 x normally open | DC PNP | 40 x 26 x 47 mm | |
IN511A | 4 mm | 0...3.24 mm | normally open | DC PNP | 40 x 12 x 26 mm |
IN512A | 4 mm | 2 x normally open | DC PNP | 40 x 26 x 26 mm | |
NE5001 | 1 mm | normally closed | DC NAMUR | M8 x 1 / L = 30 mm | |
NE5012 | 1 mm | normally closed | DC NAMUR | M8 x 1 / L = 30 mm | |
NF5001 | 2 mm | normally closed | DC NAMUR | M12 x 1 / L = 30 mm | |
NF5002 | 2 mm | normally closed | DC NAMUR | M12 x 1 / L = 30 mm | |
NF5003 | 4 mm | normally closed | DC NAMUR | M12 x 1 / L = 30 mm | |
NF5004 | 4 mm | normally closed | DC NAMUR | M12 x 1 / L = 30 mm | |
NF5008 | 4 mm | normally closed | DC NAMUR | M12 x 1 / L = 30 mm | |
NF500A | 7 mm | normally closed | DC NAMUR | M12 x 1 / L = 50 mm | |
NF5010 | 4 mm | normally closed | DC NAMUR | M12 x 1 / L = 30 mm | |
NF5012 | 2 mm | normally closed | DC NAMUR | M12 x 1 / L = 30 mm | |
NF501A | 4 mm | 0...3.24 mm | normally closed | DC NAMUR | M12 x 1 / L = 45 mm |
NF5030 | 4 mm | normally closed | DC NAMUR | M12 x 1 / L = 30 mm | |
NF504A | 0.05...0.5; (on the turbine wheel) mm | normally closed | DC | M12 x 1 / L = 33 mm | |
NF505A | 4 mm | normally closed | DC NAMUR | M12 x 1 / L = 30 mm | |
NG5001 | 5 mm | normally closed | DC NAMUR | M18 x 1 / L = 33 mm | |
NG5002 | 5 mm | normally closed | DC NAMUR | M18 x 1 / L = 33 mm | |
NG5003 | 8 mm | normally closed | DC NAMUR | M18 x 1 / L = 33 mm | |
NG5004 | 8 mm | normally closed | DC NAMUR | M18 x 1 / L = 33 mm | |
NG500A | 12 mm | normally closed | DC NAMUR | M18 x 1 / L = 51 mm | |
NG5010 | 8 mm | normally closed | DC NAMUR | M18 x 1 / L = 33 mm | |
NG5016 | 8 mm | normally closed | DC NAMUR | M18 x 1 / L = 33 mm | |
NG5019 | 5 mm | normally closed | DC NAMUR | M18 x 1 / L = 33 mm | |
NG501A | 8 mm | 0...6.48 mm | normally closed | DC NAMUR | M18 x 1 / L = 46 mm |
NG5021 | 8 mm | normally closed | DC NAMUR | M18 x 1 / L = 33 mm | |
NI5001 | 10 mm | normally closed | DC NAMUR | M30 x 1.5 / L = 41 mm | |
NI5002 | 10 mm | normally closed | DC NAMUR | M30 x 1.5 / L = 41 mm | |
NI5003 | 15 mm | normally closed | DC NAMUR | M30 x 1.5 / L = 41 mm | |
NI5004 | 15 mm | normally closed | DC NAMUR | M30 x 1.5 / L = 41 mm | |
NI500A | 22 mm | normally closed | DC NAMUR | M30 x 1.5 / L = 50 mm | |
NI5011 | 15 mm | normally closed | DC NAMUR | M30 x 1.5 / L = 41 mm | |
NI5012 | 10 mm | normally closed | DC NAMUR | M30 x 1.5 / L = 41 mm | |
NI501A | 15 mm | 0...12.15 mm | normally closed | DC NAMUR | M30 x 1.5 / L = 50 mm |
NM500A | 20 mm | normally closed | DC NAMUR | 40 x 40 x 66 mm | |
NM501A | 35 mm | normally closed | DC NAMUR | 40 x 40 x 66 mm | |
NN5001 | 2 mm | normally closed | DC NAMUR | 40 x 12 x 26 mm | |
NN5002 | 4 mm | normally closed | DC NAMUR | 40 x 12 x 26 mm | |
NN5020 | 4 mm | normally closed | DC NAMUR | 40 x 12 x 26 mm | |
NS5002 | 2 mm | normally closed | DC NAMUR | 28 x 10 x 16 mm | |
NS5003 | 2 mm | normally closed | DC NAMUR | 28 x 10 x 16 mm | |
NT5001 | 1 mm | normally closed | DC NAMUR | Ø 6.5 / L = 30 mm | |
NT5005 | 1 mm | normally closed | DC NAMUR | Ø 6.5 / L = 30 mm |
Alternate configurations
SKU | Description | List price | - |
---|---|---|---|
IFM-010010010 | Position Sensors - Inductive - Industrial automation applications | $0.01 | |
IFM-010010020 | Position Sensors - Inductive - Kplus - No correction factor | $0.01 | |
IFM-010010025 | Position Sensors - Inductive - IO-Link enabled sensors | $0.01 | |
IFM-010010030 | Position Sensors - Inductive - Coolant and machining applications | $0.01 | |
IFM-010010040 | Position Sensors - Inductive - High pressure cleaning applications | $0.01 | |
IFM-010010050 | Position Sensors - Inductive - Welding applications | $0.01 | |
IFM-010010060 | Position Sensors - Inductive - Mobile equipment applications | $0.01 | |
IFM-010010070 | Position Sensors - Inductive - Metal face solutions | $0.01 | |
IFM-010010080 | Position Sensors - Inductive - Ring and tube sensors | $0.01 | |
IFM-010010090 | Position Sensors - Inductive - Slot sensors | $0.01 | |
IFM-010010100 | Position Sensors - Inductive - Analog sensors | $0.01 | |
IFM-010010120 | Position Sensors - Inductive - Fail-safe | $0.01 | |
IFM-010010130 | Position Sensors - Inductive - Ferrous only solutions | $0.01 | |
IFM-010010145 | Position Sensors - Inductive - Sensors for limited space | $0.01 | |
IFM-010010165 | Position Sensors - Inductive - Sensors with long sensing range | $0.01 |
Call or text: +1 (484) 544-0506
The Supplyline team is here to help!