Pictures may not be actual SKU

ACS-H-150-R/100G | Multi-jet Hot Water Meter - Pulser - 1.5 in - 100 G/P

Product info Show all specs
Description
Accent's ACS-H-150-R/100G Multi-jet Hot Water Meter Pulser has 1.5 in connections and a 100 G/P pulse rate output - reed switch sensor
Key Specs
Mechanical Connections
1.5 in
Pressure Max
150 psi
Configuration
Base Model
Series
ACSH | Multi-jet Hot Water Meters
Size
150 | 1-1/2"
Configuration
Pulse Rate
R100G | 100 Gal/Pulse - Reed Switch
Availability Call to confirm
In Stock
Ships from PA
Typically ships within [ 0 to 2 ] days
24/7 Sales & Support 484-544-0506
$667.00 Configured Price
Headline
ACS Series Multi-Jet Hot Water Meters

ACS Series water meters use the widely accepted multi-jet principle, as a gear train drives the register totalizer dials. For pulse output meters, a reed switch sensor is attached to the outside of the lens and detects a magnet arm that has replaced one of the dial pointers. The reed switch output is a dry contact closure and does not require power.

Features & Benefits
Specifications Value
Max Temperature 194˚ F (90˚ C)
Operating Pressure 150 psi
Body Materials Cast bronze
Internals Materials Engineered thermoplastic
Magnet Materials Alnico
Accuracy (+/- % of reading) 1.5

Sensor Reed switch Totalizer only
Maximum Current 20 mA n/a
Maximum Voltage 24 Vdc or Vac n/a
Cable Length 12’ (4m) std n/a
Max cable run 2000' n/a
Additional Notes
Main Technical Data
Nominal Diameter Unit DN 150 - 1 1/2”
Maximum flow rate US gpm Qmax 88
Nominal flow rate US gpm Qn 44
Transition flow rate US gpm Qt 3.52
Minimum flow rate US gpm Qmin 0.88
Minimum reading US gallon 0.1
Minimum graduation US gallon 0.05
Exploded view