Product details
Spot an error? Let us know!
Headline
ACS Series Multi-Jet Hot Water Meters
ACS Series water meters use the widely accepted multi-jet principle, as a gear train drives the register totalizer dials. For pulse output meters, a reed switch sensor is attached to the outside of the lens and detects a magnet arm that has replaced one of the dial pointers. The reed switch output is a dry contact closure and does not require power.
Features & Benefits
Specifications | Value |
---|---|
Max Temperature | 194˚ F (90˚ C) |
Operating Pressure | 150 psi |
Body Materials | Cast bronze |
Internals Materials | Engineered thermoplastic |
Magnet Materials | Alnico |
Accuracy (+/- % of reading) | 1.5 |
Sensor | Reed switch | Totalizer only |
---|---|---|
Maximum Current | 20 mA | n/a |
Maximum Voltage | 24 Vdc or Vac | n/a |
Cable Length | 12’ (4m) std | n/a |
Max cable run | 2000' | n/a |
Additional Notes
Main Technical Data
Nominal Diameter | Unit | DN | 075 - 3/4” | 100 - 1” | 150 - 1 1/2” | 200 - 2” |
---|---|---|---|---|---|---|
Maximum flow rate | US gpm | Qmax | 22 | 30.8 | 88 | 132 |
Nominal flow rate | US gpm | Qn | 11 | 15.4 | 44 | 66 |
Transition flow rate | US gpm | Qt | 0.88 | 1.23 | 3.52 | 5.3 |
Minimum flow rate | US gpm | Qmin | 0.22 | 0.31 | 0.88 | 1.32 |
Minimum reading | US gallon | 0.01 | 0.01 | 0.1 | 0.1 | |
Minimum graduation | US gallon | 0.005 | 0.005 | 0.05 | 0.05 |
Exploded view
Call or text: +1 (484) 544-0506
The Supplyline team is here to help!