Methylene Chloride (Dichloromethane)

Formula CH2Cl2 · CAS 75-09-2

Also called DCM, Freon-30, MDC, Methylene dichloride, R-30, Refrigerant-30

Pumping notes
Temperature-sensitive

What people pick

HeadPTFE (Teflon)
SealsFFKM or PTFE (Teflon)

FKM is B; expect swelling.

Also works
PVDF (Kynar), FKM (Viton)
Avoid
PVC (rigid), Polypropylene, CPVC, EPDM, Nitrile (Buna-N, NBR)
If it must be metal
Hastelloy C / Alloy C (grade not stated)Hastelloy C rates A; 316 also A, with caution.
Peristaltic tubing
No pump tube suits it: Flex-A-Prene C, Flex-A-Chem D, Flex-A-Thane D.
  • PTFE only
  • Attacks plastics
  • Seal choice is critical
  • Heat-sensitive
  • FKM, not EPDM
Why

Methylene chloride attacks PVC and PP (D); PVDF (Kynar) is only B, and only when kept cool. PTFE is the head rated A, or 316 stainless or Hastelloy C. FFKM is the only elastomer rated A; FKM (Viton) is B and EPDM fails.

From our applications engineers. Every pick is rated A or B by the guides at that strength.

13 of 13 materials

MaterialStrength not stated
metal
plastic
Usual pick
metal
elastomer
plastic
plastic
Avoid
plastic
plastic
Avoid
plastic
elastomer
Avoid
plastic
plastic
Avoid
elastomer

What the guides note

“Methylene Chloride => Dichloro Methane”

ProMinent, p5 r54
  • Excellent
  • Good
  • Fair
  • Poor
  • Estimate
  • – No data

Bars: our confidence, 1 to 3. A temperature under the bars is the lowest limit a guide states. Orange dot: use with care; open the rating for why. Grey: an estimate, because no guide rates it. Select any rating for the detail.

Ratings combine published chemical guides, weighted, with Cole-Parmer's printed chart breaking ties. Check the maker and your own conditions before you order. Dataset 2026-11-16-7f6e10a9