Methylene Chloride (Dichloromethane)
Formula CH2Cl2 · CAS 75-09-2
Also called DCM, Freon-30, MDC, Methylene dichloride, R-30, Refrigerant-30
What people pick
FKM is B; expect swelling.
- Also works
- PVDF (Kynar), FKM (Viton)
- Avoid
- PVC (rigid), Polypropylene, CPVC, EPDM, Nitrile (Buna-N, NBR)
- If it must be metal
- Hastelloy C / Alloy C (grade not stated)Hastelloy C rates A; 316 also A, with caution.
- Peristaltic tubing
- No pump tube suits it: Flex-A-Prene C, Flex-A-Chem D, Flex-A-Thane D.
- PTFE only
- Attacks plastics
- Seal choice is critical
- Heat-sensitive
- FKM, not EPDM
Why
Methylene chloride attacks PVC and PP (D); PVDF (Kynar) is only B, and only when kept cool. PTFE is the head rated A, or 316 stainless or Hastelloy C. FFKM is the only elastomer rated A; FKM (Viton) is B and EPDM fails.
From our applications engineers. Every pick is rated A or B by the guides at that strength.
13 of 13 materials
| Material | Strength not stated |
|---|---|
| metal | |
| plastic Usual pick | |
| metal | |
| elastomer | |
| plastic | |
| plastic Avoid | |
| plastic | |
| plastic Avoid | |
| plastic | |
| elastomer Avoid | |
| plastic | |
| plastic Avoid | |
| elastomer |
What the guides note
“Methylene Chloride => Dichloro Methane”
- Excellent
- Good
- Fair
- Poor
- Estimate
- – No data
Bars: our confidence, 1 to 3. A temperature under the bars is the lowest limit a guide states. Orange dot: use with care; open the rating for why. Grey: an estimate, because no guide rates it. Select any rating for the detail.