Bromine

Formula Br2 · CAS 7726-95-6

Pumping notes
Off-gassing
Used asBiocides

What people pick

HeadPVDF (Kynar)
SealsFKM (Viton)
Also works
PTFE (Teflon), FFKM
Avoid
PVC (rigid), Polypropylene, CPVC, EPDM, Hypalon (CSPE / CSM), Aflas (TFE/P, FEPM), Nitrile (Buna-N, NBR), 316 stainless steel
If it must be metal
Hastelloy C / Alloy C (grade not stated)
Peristaltic tubing
No pump tube suits it: Flex-A-Prene D, Flex-A-Chem D, Flex-A-Thane D.
  • PVDF preferred
  • FKM, not EPDM
  • Seal choice is critical
  • Avoid 316
Why

Liquid bromine attacks most plastics and seals: PVDF (Kynar) or PTFE wetted parts with FKM (Viton) seals are the pick, all rated excellent. PVC is rated fair to poor, and PP, CPVC, EPDM, CSPE (Hypalon) and 316 stainless are rated not recommended. Hastelloy C is the metal if one is needed.

From our applications engineers. Every pick is rated A or B by the guides at that strength.

13 of 13 materials

MaterialStrength not stated
metal
plastic
plastic
Usual pick
elastomer
Usual pick
plastic
Avoid
elastomer
Avoid
metal
Avoid
plastic
Avoid
elastomer
Avoid
plastic
Avoid
plastic
plastic
plastic
  • Excellent
  • Good
  • Fair
  • Poor
  • – No data

Bars: our confidence, 1 to 3. A temperature under the bars is the lowest limit a guide states. Orange dot: use with care; open the rating for why. Select any rating for the detail.

Ratings combine published chemical guides, weighted, with Cole-Parmer's printed chart breaking ties. Check the maker and your own conditions before you order. Dataset 2026-11-16-7f6e10a9