W900 Series Water Treatment Controllers
Enjoy unparalleled versatility and powerful programming for complete control of chemical metering pumps and valves in a broad range of water treatment applications.
Features:
- Powerful Control
- WiFi, BACnet, Graph Reports
- Flexible Programming
- Online Access
- Easy Setup
- Great Value
Benefits:
-
Large touchscreen display with icon based programming makes setup easy
-
Universal sensor input provides extraordinary flexibility; the same controller can be used with almost any type of sensor needed
-
Four I/O slots allow complete flexibility in adding additional sensors, analog inputs and analog outputs
-
Multiple language support allows simple setup
-
Eight relay control outputs allow the controller to be used in more applications
-
Economical wall-mount package for easy installation
-
On-screen and web page graphing of sensor values and control output status
-
Complete function of each relay
- On/Off Setpoint
- Time Proportional Control
- Pulse Proportional Control (when purchased with 4-20 mA or pulse solid state opto outputs)
- Flow Proportional Control (when purchased with 4-20 mA or pulse solid state opto outputs)
- PID control (when purchased with 4-20 mA or pulse solid state opto outputs)
- In-Range or Out-of-Range activation
- Probe wash
- Timer-based activation
- Activation based upon the state of a contact closure
- Timed activation triggered by Water Contactor / Paddlewheel flow meter’s accumulated total flow
- Activate with another output
- Activate as a percent of another output’s on-time
- Alarm
- Spike Set Point
- PPM Volume
- Target PPM
- For Cooling Tower and Boiler applications:
- Biocide Timer
- Boiler blowdown on conductivity using intermittent sampling
-
Ethernet for remote access via the Internet, LAN or optional Modbus/TCP
-
Datalogging
-
Email Alarm messages, Datalog reports or System Summary reports
Specifications:
Inputs
Power 100-240 VAC, 50 or 60 Hz, 13A max Fuse: 6.3 Amp
Sensor Input Signals (0-8 depending on model code)
Contacting Conductivity: 0.01, 0.1, 1.0, or 10.0 cell constant, or
Electrodeless Conductivity or
Disinfection or
Amplified pH, ORP, or Ion Selective Electrode which requires a preamplified signal. ±5VDC power available for external
preamps. Walchem WEL or WDS series pH/ORP sensors recommended.
Each sensor input card contains a temperature input.
Temperature: 100 or 1000 ohm RTD, 10K or 100K Thermistor
Analog (4-20 mA) Sensor Input (0-24 depending on model code) 2-wire loop powered and self-powered transmitters supported 3-wire and 4-wire transmitters supported All Channels fully isolated, input and power Channel 1, 130 ohm input resistance, Channel 2-6, 280 ohm input resistance Available Power: Isolated 24 VDC ±15% supply per channel. 1.5 W (62.5 mA maximum for each channel)
Digital Input Signals (12): State-Type Digital Inputs Electrical: Optically isolated and providing an electrically isolated 12V power with a nominal 2.5 mA current when the digital input switch is closed. Typical response time: < 2 seconds. Devices supported: Any isolated dry contact (i.e. relay, reed switch). Types: DI State
Low Speed Counter-Type Digital Inputs Electrical: Optically isolated and providing an electrically isolated 12V power with a nominal 2.5 mA current when the digital input switch is closed, 0-20 Hz, 25 msec minimum width. Devices supported: Any device with isolated open drain, open collector, transistor or reed switch. Types: Contacting Flowmeter
High Speed Counter-Type Digital Inputs Electrical: Optically isolated and providing an electrically isolated 12V power with a nominal 2.5 mA current when the digital input switch is closed, 0-500 Hz, 1.0 msec minimum width. Devices supported: Any device with isolated open drain, open collector, transistor or reed switch. Types: Paddlewheel Flowmeter
Outputs
Powered Mechanical Relays (0-8 model code dependent) Pre-powered on circuit board switching line voltage Four relays are fused together as one group, total current must not exceed 6.3A (resistive), 1/8 HP (93W)
Dry Contact Mechanical Relays (0-8 model code dependent) 6 A (resistive), 1/8 HP (93W) Dry contact relays are not fuse protected.
Pulse Outputs (0-4 model code dependent) Opto-isolated, solid-state relay, 200mA, 40V DC VLOWMAX = 0.05V @ 18mA
4 - 20 mA (0-16 model code dependent) Internally powered, 15VDC, Fully isolated 600 ohm max resistive load Resolution 0.0015% of span Accuracy ± 0.5% of reading
SKU | Description | List price | - |
---|---|---|---|
WAL-WIN900HNNNNDMNNNNNN | WIN900H-NNNN-DM-N-NNNNN | W900 Disinfection Controller - 8 Powered - Hardwired - Ethernet & WiFi - Modbus - No Sensors | $3,456.00 | |
WAL-WIN900HNNNNDNNNNNNN | WIN900H-NNNN-DN-N-NNNNN | W900 Disinfection Controller - 8 Powered - Hardwired - Ethernet & WiFi - No Comms - No Sensors | $3,115.00 | |
WAL-WIN900HNNNNNMNNNNNN | WIN900H-NNNN-NM-N-NNNNN | W900 Disinfection Controller - 8 Powered - Hardwired - No WiFi - Modbus - No Sensors | $3,229.00 | |
WAL-WIN900HNNNNNNNNNNNN | WIN900H-NNNN-NN-N-NNNNN | W900 Disinfection Controller - 8 Powered - Hardwired - No WiFi - No Comms - No Sensors | $2,890.00 | |
WAL-WIN900HNNNNWNNNNNNN | WIN900H-NNNN-WN-N-NNNNN | W900 Disinfection Controller - 8 Powered - Hardwired - WiFi - No Comms - No Sensors | $3,115.00 | |
WAL-WIN900HxxxxDMxxxxxx | WIN900H-xxxx-DM-xxxxxx | W900 Disinfection Controller - 8 Powered - Hardwired - Ethernet & WiFi - Modbus - Configurable | $3,456.00 | |
WAL-WIN900HxxxxDNxxxxxx | WIN900H-xxxx-DN-xxxxxx | W900 Disinfection Controller - 8 Powered - Hardwired - Ethernet & WiFi - No Comms - Configurable | $3,115.00 | |
WAL-WIN900HxxxxNMxxxxxx | WIN900H-xxxx-NM-xxxxxx | W900 Disinfection Controller - 8 Powered - Hardwired - No WiFi - Modbus - Configurable | $3,229.00 | |
WAL-WIN900HxxxxNNxxxxxx | WIN900H-xxxx-NN-xxxxxx | W900 Disinfection Controller - 8 Powered - Hardwired - No WiFi - No Comms - Configurable | $2,890.00 | |
WAL-WIN900HxxxxWMxxxxxx | WIN900H-xxxx-WM-xxxxxx | W900 Disinfection Controller - 8 Powered - Hardwired - WiFi - Modbus - Configurable | $3,456.00 | |
WAL-WIN900HxxxxWNxxxxxx | WIN900H-xxxx-WN-xxxxxx | W900 Disinfection Controller - 8 Powered - Hardwired - WiFi - No Comms - Configurable | $3,115.00 | |
WAL-WIN900PNNNNDMNNNNNN | WIN900P-NNNN-DM-N-NNNNN | W900 Disinfection Controller - 8 Powered - Prewired - USA - Ethernet & WiFi - Modbus - No Sensors | $3,632.00 | |
WAL-WIN900PNNNNDNNNNNNN | WIN900P-NNNN-DN-N-NNNNN | W900 Disinfection Controller - 8 Powered - Prewired - USA - Ethernet & WiFi - No Comms - No Sensors | $3,292.00 | |
WAL-WIN900PNNNNNMNNNNNN | WIN900P-NNNN-NM-N-NNNNN | W900 Disinfection Controller - 8 Powered - Prewired - USA - No WiFi - Modbus - No Sensors | $3,405.00 | |
WAL-WIN900PNNNNNNNNNNNN | WIN900P-NNNN-NN-N-NNNNN | W900 Disinfection Controller - 8 Powered - Prewired - USA - No WiFi - No Comms - No Sensors | $3,066.00 |
The Supplyline team is here to help!