Pictures may not be actual SKU

EX100/200 Adjustable Depth Insertion Magmeters

Product info
EX100 | EX100/200 Adjustable Depth Insertion Magmeters
Description
Seametrics EX 100/200 Adjustable Depth Paddlewheel Magmeters and EX 150/250 for Hot-tap installations
Configuration Model Codes
Base Model
Series
EX | Insertion Electromagnetic Flow Sensor
Availability Call to confirm
Select model  or  search within  this product range
Models are:  In Stock
Ships from Pennsylvania
Typically ships within [ 0 to 2 ] days
24/7 Sales & Support 484-544-0506
Headline

EX100/200

Adjustable Depth Insertion Magmeter

EX150/250

Hot-Tap Adjustable Depth Insertion Magmeter

Features & Benefits
EX100/200 Features:
  • Depth adjustable sensors
  • EX110 fits any 1-1/2″ pipe fitting (standard saddle, for instance) and adjusts to pipe sizes 3-10″
  • EX210 adjusts to pipe sizes 10-48″
  • Meter extends only about 1/8 of pipe diameter, minimizing potential for clogging with debris
  • Accept Seametrics modules for rate and total indication, 4-20 mA conversion, data logging, and flow switching
  • Alternatively, signal can be sent directly to a PLC or other control
  • Available in brass or 316 stainless steel
  • Immersibility and reverse flow output available
  • Certified to NSF/ANSI 61 Standard (stainless version)
EX150/250 Features:
  • Isolation valve allows installation and removal under pressure
  • Useful in large water utility pipe and other applications where shutdown is not an option
  • EX150 fits pipe from 3″ to 10″
  • EX250 fits pipe from 10″ to 48″
  • Meter extends only about 1/8 of pipe diameter, minimizing potential for clogging with debris
  • In most applications, installation tool not necessary due to small tube diameter
  • Available in brass or 316 stainless steel
  • Standard valve material is brass, with stainless optional
  • Certified to NSF/ANSI 61 Standard (stainless version)
Additional Notes
Specs Value
Pipe Size 3” to 48” (up to 72” optional)
Power Full Power: 12 - 24 Vdc, 250mA Low Power: 12 - 24 Vdc, 40mA average with 250mA peaks
Housing Materials Powder-coated cast aluminum
Tubing/Fitting/Sensor Housing Materials Brass or 316 Stainless Steel
Electrodes Materials Hastelloy
Electrode Cap Materials PVDF
O-Ring Materials (15x/25x only) EPDM
Valve Assembly Materials (15x/25x only) Bronze (stainless optional) with bronze ball valve
Fitting Size Required 11x/21x: 1.5” FNPT 15x/25x: 2” FNPT
Maximum Pressure 200 psi (14 bar)
Ambient Temperature 0˚ to 160˚ F (-17˚ to 72˚ C)
Fluid Temperature 32˚ to 200˚ F (0˚ to 93˚ C)
Minimum Conductivity 20 microSiemens/cm
Flow Velocity 0.28 - 20 ft/sec (0.08 - 6.09 m/sec)
Accuracy ± 1% of full scale
Output Square wave pulse, opto-isolated, 500 Hz @ 20 ft/sec
6 mA max, 30Vdc forward flow standard; reverse flow optional
Empty Pipe Detection Software, defaults to zero flow
Cable Standard 18’ (6m), #22 shielded twisted pair, 4-conn. Max. cable run at 24 Vdc = 1000’ (300m); at 12 Vdc = 500’ (150m). For other circumstances, contact the factory.
Environmental See meter mounted electronic specification for rating.
Regulatory Mark (applies to full power sensor only configuration and full power FT 430/440 mounted configurations).
Certified to NSF/ANSI standard 61 and NSF 372 (Stainless only)
Call or text: +1 (484) 544-0506

The Supplyline team is here to help!